The controller does not display anything after the power-on. Why?
Ensure that the power supply is as specified in the specification. When the EMG terminal is open, the power will not be turned on. Please check the interlock function and the power up procedure in the specifications.
Why does the controller's fuse blow after powering on?
Because the controller's power supply has positive and negative polarity, please ensure the polarity is correct before wiring.
The speed is changed using the teaching box, but returned to the original speed after the power-on again. Why?
You cannot change speed if the input speed value is out of the setting range. Data writing is required after setting the speed. Please follow the procedure to write to EEPROM. See the Instruction Manual as the procedure varies depending on the models.
Error 08 occurs when the robot is moved up and down with the arm extended. Why?
When the arm is extended, the vertical movement amount is restricted by the setting. Check the operating range and change the setting of vertical movement amount in accordance with the Instruction Manual.
Why is the speed of the G-series robot very slow when executing ORG to return to the origin after clearing an error?
Because the G-series robot has a movement restriction zone. Once the arm leaves this zone, the speed will return to normal.